Our products

Our products

All our products are handmade in our workshops. If needed you can call on our experts who will be happy to advise you. We also create custom transformers.

Presentation

Connection by pod

Connection by flexible wire


Primary

Secondary

Volt (V)

Midpoint

Ampere (A)

Add an output

Total output power

0VA

Presentation

Connection by pod

Connection by flexible wire


Primary (kΩ)

Front outlet

%

Secondary


Specifications

Transformer output

W

Type

Autotransformers

COMPLIES WITH IEC 61558-2-13 STANDARDS

 

The autotransformer has one winding. Its main function is to adapt the voltage to the need. It is, by construction, reversible. Its size is smaller and cheaper for the same amount of power than an isolation transformer. 

 

Its level of performance is better, it has small losses because there are less used materials. However, it has not galvanic isolation.

Safety transformers

COMPLIES WITH IEC 61558-2-6 STANDARD

 

The safety transformer brings security to people and command. Close enough to a circuit separation or isolating transformer, the safety transformer has the secondary voltage below 50V. It is used to control/command applications or automatism.

Circuit separation transformers

COMPLIES WITH STANDARDS NF EN 60742 * or WITH STANDARD NFC 52210

 

The circuit separation transformer, also known as isolating transformer (From a power of 6.3kVA), insulates galvanically a device or an installation from electrical disturbances.

Besides the adaptation of the voltage, it allows the change of the neutral point connection. With an electrostatic screen, the transformer mitigated the disruption of high frequency. Connected in triangle, it deletes harmonics from rank 3.

Circuit separation transformers, medical use

COMPLIES WITH CEI/IEC 61558 - 1/- 2/-2-15

 

The isolating transformers (medical use) are adapted for use in medical buildings as hospitals or medical rooms as operating rooms, shock rooms, dental practices… 

They are fitted with thermal probes which allow a temperature protection to avoid possible damages caused by an increase of the temperature in the transformer.

They are fully compliant with CEI/IEC 61558 - 1/- 2/-2-15 with very specific characteristics (UCC < 3%, Inrush current < 12In, …). The galvanic isolation is strengthened. The secondary voltage needs to be 250V or less.

Three-Phase/Single-Phase transformers

THREE-PHASE/SINGLE-PHASE TRANSFORMERS COMPLYING WITH CEI 61558-2-4 AND CEI 76-726

Function: The isolating transformer three/single phase (TRI/MONO) allows to move from a primary three-phase network (Y) to a secondary single-phase network by mitigating instability without removing it. Its characteristics are similar to a standard isolating transformer.
Type: TTM-TTMP
Power: From 630VA to 250kVA
Primary voltage: 400V three-phase
Secondary voltage: 230V single-phase
Coupling: Single-phase/three-phase
Frequency: 50/60Hz
Magnetic circuit: Grain oriented electric sheet with low losses.
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class H insulation, electrostatic shield between primary and secondary.
Tropicalisation: On request
Connectivity: Inputs and outputs on marked terminal blocks.
Imbalance: 33% backfeed on power supply.

Transformers for single-phase machine-tool equipment

TRANSFORMER FOR SINGLE-PHASE MACHINE-TOOL EQUIPMENT COMPLYING WITH IEC/EN 61558-1 / 61558-2-4*, -2-6**

Transformers for single-phase machine-tool equipment allows the power supply of circuits with various tensions. It can fit different needs from various power sources (230V or 400V).

Type: TRMO
Power: 40VA to 1600VA (permanent stock). Other powers on request.
Coupling: For secondary voltage, parallel series.
Frequency: 50/60Hz
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class H insulation.
Isolation: 4000V between windings and ground, and between windings.
Tropicalisation: On request.
Connectivity: Inputs and outputs on marked terminal blocks.
Voltage drops: Limited to 3% for cosω= 0,45

Transformers for command circuit boards (CNOMO-COMPLIANT)

TRANSFORMERS FOR COMMAND CIRCUIT BOARDS, (CNOMO-COMPLIANT) COMPLYING WITH IEC/EN 61558-2-2.2-4, 2-6 / CNOMO E 0322210N

Type: TFCE or TDCE
Power: 63A/1600VA (permanent stock)
Usual voltage: 230V/400V//115V/230V or 24/48V
Frequency: 50/60Hz
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class F insulation.
Isolation: 4000V between windings and ground, and between windings.
Voltage drop: For full load, limited to 3% to cosj = 0,45
Coupling: Series or parallel on secondary winding with 2 electrostatic shields.

Protection:
TFCE: With fuse holder, delivered without fuse
PRI: 2 short-circuits 10.3x38 (6mm2)
SEC: short-circuits 8.5x31.5(6mm2)

TDCE
PRI: 2 short-circuits 10.3x38 (6mm2)
SEC: Bipolar magnetic circuit breaker with a type C response curve.

Filtered rectified single-phase power supplies

FILTERED RECTIFIED SINGLE-PHASE POWER SUPPLIES COMPLYING WITH IEC/EN 61558-2-6

Power supplies allows to move from an alternative voltage to a rectified voltage. 

Filtered : Output current is rectified and filtered

Type: RF
Composed of:
- A safety transformer with electrostatic shield, output on secondary-side screw terminal
- Inputs and outputs on terminals
- Fuse-protected on secondary
- A filter capacitor
IP00 uncovered overview
Primary: 230/400V ± 15 V.CA
Secondary: 24V or 48V DC
Frequency: 50-60Hz
Class: 1
Ripple: <5%

Non-filtered rectified single-phase power supplies

NON-FILTERED RECTIFIED SINGLE-PHASE POWER SUPPLIES COMPLYING WITH IEC/EN 61558-2-6

Power supplies allows to move from an alternative voltage to a rectified voltage. 

Unfiltered : Output current is rectified and unfiltered

Type: RNF
Composed of:
- A safety transformer with electrostatic shield, output on secondary-side screw terminal
- Inputs and outputs on terminals
- Fuse-protected on secondary
IP00 uncovered (bare) composition
Primary: 230/400V ± 15 V.CA
Secondary: 24V or 48V DC
Frequency: 50-60Hz
Class: 1
Ripple: 47%

Transformers for printed circuit boards

TRANSFORMERS FOR PRINTED CIRCUIT BOARDS COMPLYING WITH CEI 61558 AND CEI 742

Function: Transformers for printed circuit boards are usually small power (< à 40VA). It allows an integration on circuit board (Assembly with solder pins).
Type: TSCI-TSMCI
Power: From 1VA to 30VA
Primary voltage: 230V
Secondary voltage: 2 x 6V ; 2 x 9V ; 2 x 12V ; 2 x 15V ; 2 x 18V ; 2 x 24V
Coupling: For secondary voltage, series or parallel
Frequency: 50/60Hz
Isolation: Above 4000V between primary and secondary
Connectivity: Inputs and outputs via pins

Toroidal transformers

TOROIDAL TRANSFORMERS COMPLYING WITH EN 60950, EN 60065 AND CEI 61558

Function: Toroidal transformers are like safety and circuit separation transformers but with a reduce weight and size. They are often used in LED lights. They can be manufactured in standard or tailor-made according to your characteristics. 
Type: TT
Power: 20VA to 630VA (permanent stock). Other power levels on request.
Coupling: For secondary voltages, series, parallel.
Frequency: 50/60Hz
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class F insulation.
Isolation: 4000V between windings and ground, and between windings.
Connectivity: Inputs and outputs via 20cm wire
Accessories: Transformer comes with 1 rounded steel cup and 2 rubber washers.

Connectivity
Power supply transformer
Output transformer

Output Transformers: Allows adaptation of impedances.

Selfs
Clear AC

Uses : Tri-Galvanic isolation transformer connected to the ground circuit, RFI Filter with inductance and capacitors, this material is particularly recommended for the alimentation of all sensitive materials as : medical devices, numerical control machine-tools, high-end hifi amplifier, hardware and devices…

Hyper insulation triple screen transformers
Toroidal audio transformers

COMPLYING WITH EN 60950, EN 60065 AND CEI 61558

Function: Toroidal transformers are like safety and circuit separation transformers but with a reduce weight and size. They can be manufactured in standard or tailor-made according to your characteristics. 
Type: TT
Power: 20VA to 630VA (Permanent stock). Other power levels on request.
Coupling: For secondary voltages, series, parallel.
Frequency: 50/60Hz.
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class F insulation.
Isolation: 4000V between windings and ground, and between windings.
Connectivity: Inputs and outputs via 20cm wire.
Accessories: Transformer comes with 1 rounded steel cup and 2 rubber washers.
Primary: 230V Secondary from 1 to 2 outputs: 12V, 2x24V, 115V, 230V...

SPECIAL TOROIDAL TRANSFORMERS: Please contact us
Overview:
Uncovered type IP00: For assembly in enclosure
ON REQUEST
Waterproof Type IP44: Mouled cover enclosure

Audio transformer finishes
Single-Phase

Function: Adapts the voltage as needed
Type: ATR-ATRP
Power: 40VA to 63kVA (permanent stock)
Usual voltage: 230V, 400V.
Frquency: 50/60Hz.
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class H insulation.
Isolation: 4000V between windings and ground
Tropicalisation: On request
Connectivity: Inputs and outputs on marked terminal blocks.

Plain enclosure
1 or 2 outputs
Uncovered model
Uncovered model
Uncovered model

FUNCTION: Tube amplifier power supply, stereo and guitar.
Power: From 10VA to 1600VA as standard and up to 5000VA on request.
Coupling: Single-phase
Frequency: 50/60 Hz.
Magnetic circuit: Grain-oriented crystal sheets oriented at low losses.
Winding: Enameled electrolytic copper class H, treated and polymerized in an oven, varnish class H, insulating class H, electrostatic screen between primary and secondary.
Connection: Inputs and outputs on solder terminals or on flexible wires.
Efficiency: Above 95% , weak heating.
Model: Uncovered

Examples: 230V // 230v / 2 x 6.3v230v // 400v / 230v / 6.3v

On consultation: Above 3 voltages, allow 5 € TTC per additional voltages.

Single-Phase

Use: Power supply for medical use, designed to be connected permanently to the fixed wiring of the IT (impedant earth) power system.
Type: ISOLUM (Single-Phase)
Power: 3kVA ≤ P ≤ 10kVA
Primary voltage: ≤ 1000V. Usual: 230V single-phase ; 400V three-phase.
Secondary voltage: ≤ 250V. Usual: 230V between phases.
Coupling (Three-phase): Star + Neutral // Star + Neutral.
Frequency: ≤ 500Hz. Usual: 50/60Hz.
Special characteristics: Impedance voltage ≤ 3 %. Inrush current ≤ 12In. (8 In as standard)
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class H insulation, electrostatic shield between primary and secondary.
Connectivity: Inputs, outputs and shield on marked terminal blocks with insulators.

Single-Phase

Function: In addition to adapting the voltage, it allow circuit isolation, change of system neutral and parasite filtering.
Type: ISOL-ISOLP
Power: 40VA to 63kVA (permanent stock). Other powers on request.
Usual voltage: 230V, 400V.
Coupling: On request.
Frequency: 50/60Hz.
Winding: Class screen enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class B insulation, electrostatic screen between primary and secondary.
Isolation: 4000V between windings and ground, and between windings.
Tropicalisation: On request
Connectivity: Inputs and outputs on marked terminal blocks.
Protection: The protection rating is indicated on the Transformer Identification Plate.

Single-Phase

Function: Power SLEV -safety extra-low voltage) circuits and PELV (protected extra-low voltage) circuits,
Type: TS-TSP
Power: 40VA to 5000VA (permanent stock). Higher power available on request.
Usual voltage: 230V, 400V, 12V, 24V, 48V
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class F insulation, electrostatic screen between primary and secondary.
Isolation: 4000V between windings and ground, and between windings.
Tropicalisation: On request
Connectivity: Inputs and outputs on marked terminal blocks.
Protection: The protection rating is indicated on the Transformer Identification Plate.

Three-phase

Use: Power supply for medical use, designed to be connected permanently to the fixed wiring of the IT (impedant earth) power system.
Type: ISOLTUM (Three-Phase)
Power: 3kVA ≤ P ≤ 10kVA
Primary voltage: ≤ 1000V. Usual: 230V single-phase ; 400V three-phase.
Secondary voltage: ≤ 250V. Usual: 230V between phases.
Coupling (Three-phase): Star + Neutral // Star + Neutral.
Frequency: ≤ 500Hz. Usual: 50/60Hz.
Special characteristics: Impedance voltage ≤ 3 %. Inrush current ≤ 12In. (8 In as standard)
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class H insulation, electrostatic shield between primary and secondary.
Connectivity: Inputs, outputs and shield on marked terminal blocks with insulators.

Three-phase

Function: In addition to adapting the voltage, it allows circuit isolation, change of system neutral and parasite filtering.
Type: ISOL-ISOLP
Power: 630VA to 250kVA
Usual votlage: 230V, 400V.
Coupling: Dyn11 or on demand.
Frequency: 50/60Hz.
Magnetic circuit: Grain oriented electric sheet with low losses.
Winding: Class H, enamelled electrolytic copper and polymerized in an oven, class H varnish, class H insulation, electrostatic screen between primary and secondary.
Isolation: 4000V between windings and ground, and between windings.
Tropicalisation: On request.
Connectivity: Inputs and outputs on marked terminal blocks or copper bar.

Chromed enclosure model

FUNCTION: Tube amplifier power supply, stereo and guitar.
Power: From 10VA to 1600VA as standard and up to 5000VA on request.
Coupling: Single-phase
Frequency: 50/60 Hz.
Magnetic circuit: Grain-oriented crystal sheets oriented at low losses.
Winding: Enameled electrolytic copper class H, treated and polymerized in an oven, varnish class H, insulating class H, electrostatic screen between primary and secondary.
Connection: Inputs and outputs on solder terminals or on flexible wires.
Efficiency: Above 95% , weak heating.
Model: Chromed enclosure

Examples: 230V // 230v / 2 x 6.3v230v // 400v / 230v / 6.3v

On consultation: Above 3 voltages, allow 5 € TTC per additional voltages.

Chromed enclosure model
Chromed enclosure model
Three-phase

Function: Adapts the voltage as needed
Type: ATRT-ATRTP
Power: 630VA to 63kVA (permanent stock)
Usual voltage: 230V, 400V
Frequency: 50/60Hz
Magnetic circuit: Grain oriented electric sheet with low losses
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class H insulation.
Isolation: 4000V between windings and ground.
Tropicalisation: On request
Connectivity: Inputs and outputs on marked terminal blocks or copper bar.

3,4 or 5 outputs
Three-phase

Function: Power SELV (safety extra-low voltage) circuits and PELV (protected extra-low voltage) circuits
Type: TST-TSTP
Power: 630VA to 63kVA. Other powers on request.
Usual voltage: 230V, 400V, 24V, 42V
Coupling: ΔY,ΔY
Frequency: 50/60Hz
Winding: Class H, enamelled electrolytic copper, treated and polymerized in an oven, class H varnish, class H insulation, electrostatic screen between primary and secondary.
Isolation: 4000V between windings and ground, and between windings.
Tropicalisation: On request
Connectivity: Inputs and outputs on marked terminal blocks or copper bar.

Chromed enclosure
Tank model

FUNCTION: Tube amplifier power supply, stereo and guitar.
Power: From 10VA to 1600VA as standard and up to 5000VA on request.
Coupling: Single-phase
Frequency: 50/60 Hz.
Magnetic circuit: Grain-oriented crystal sheets oriented at low losses.
Winding: Enameled electrolytic copper class H, treated and polymerized in an oven, varnish class H, insulating class H, electrostatic screen between primary and secondary.
Connection: Inputs and outputs on solder terminals or on flexible wires.
Efficiency: Above 95% , weak heating.
Model: Tank

Examples: 230V // 230v / 2 x 6.3v230v // 400v / 230v / 6.3v

On consultation: Above 3 voltages, allow 5 € TTC per additional voltages.

Tank model
Tank model
Tank
Search:
Warning: Undefined array key "search" in /home/eso/eso-transformateurs.com/www/en/products.php on line 412

This website uses cookies

Cookies allow us to personalize the content of the site and analyze our traffic.

check Allow all cookies edit Configure